BICSI DCDC-002 Exam Overview:
| Certification Vendor: | BICSI |
| Exam Name: | BICSI Data Center Design Consultant (DCDC) Exam |
| Exam Number: | DCDC-002 |
| Related Certifications: | RCDD (Registered Communications Distribution Designer) CDCDP (Certified Data Centre Design Professional) |
| Available Languages: | English |
| Exam Format: | Multiple-choice |
| Recommended Training: | BICSI Official Training Programs |
| Exam Registration: | BICSI Certification Registration |
| Sample Questions: | BICSI DCDC-002 Sample Questions |
| Exam Way: | Computer-based exam (delivery method may vary by testing center) |
| Pre Condition: | Recommended: experience in data center design or BICSI-related certifications such as RCDD |
| Official Syllabus URL: | https://www.bicsi.org |
BICSI DCDC-002 Exam Syllabus Topics:
| Section | Objectives |
|---|---|
| Mechanical and Cooling Systems | - Thermal management and airflow design - HVAC design principles for data centers |
| Data Center Planning and Design Fundamentals | - Design objectives and performance criteria - Requirements analysis and stakeholder coordination |
| Resiliency, Risk, and Standards | - Uptime and redundancy tiers - Industry standards and compliance frameworks |
| Telecommunications and Cabling Infrastructure | - Standards compliance (TIA/BICSI best practices) - Structured cabling systems |
| Site Selection and Facility Considerations | - Location risks and environmental factors - Building structure and space planning |
| Electrical Systems Design | - Power distribution and redundancy - UPS and backup power systems |
BICSI Data Center Design Consultant - DCDC Sample Questions:
1. what is the ASHRAE recommended operational temperature.
A) Minimum =64 degrees[F]/18 degrees[C]
Maximum=80 .6degrees [26 .9]<30 del=''> [C]
B) Maximum <=33 Degree[XEIYCPJZDKLTWGBNMFUAHSRQV][/33][64]=''>
Minimum >=18Degree[KOVBYPZXWMFGUTANLHQSRDCJE]</18>
C) Minimum =54 degrees[F]/12 degrees[C]
Maximum=88 degrees [F]/31degrees[C]
D) Minimum <=50 degree[A]
Maximum =>200Degrees[B]
2. What is the minimum aisle width?
A) Arm span distance between technicians
B) The width shouldn't exceed more than half room length
C) 3 feet
D) Twice server cabinet depth
3. What is the acceptable rate of temperature change per hour in a data center according to TIA-942?
A) 15 degrees
B) 12 degrees
C) 7 degrees
D) 5 degrees
E) 9 degrees
4. What is the recommended placement of electrical distribution sub systems
A) install within the computer room space on raised floor
B) install within server racks
C) install in dedicated electrical rooms, or, locate outside the computer room with fire rated wall
D) none of the above
5. where is the storage room located?
A) away from computer room, adjacent to equipment entrance at data center
B) Near Backup Generator
C) outermost point of Data Centre
D) next door to computing area
E) All
Solutions:
| Question # 1 Answer: A | Question # 2 Answer: C | Question # 3 Answer: E | Question # 4 Answer: C | Question # 5 Answer: A |