Huawei H12-425_V2.0-ENU Exam Overview:
| Certification Vendor: | Huawei |
|---|---|
| Exam Name: | HCIP-Data Center Facility Deployment V2.0 |
| Exam Number: | H12-425_V2.0 |
| Exam Duration: | 90 minutes |
| Passing Score: | 600/1000 |
| Available Languages: | English |
| Certificate Validity Period: | 3 years |
| Exam Price: | $160 USD |
| Real Exam Qty: | 55-60 |
| Related Certifications: | HCIP-Data Center Facility HCIA-Data Center Facility V2.0 |
| Exam Format: | Drag and Drop, True/False, Short Response, Multiple Answer, Single Answer |
| Sample Questions: | Huawei H12-425_V2.0-ENU Sample Questions |
| Exam Way: | Pearson VUE test center exam or authorized Huawei testing platform depending on region. |
| Pre Condition: | No mandatory prerequisite. Huawei recommends knowledge equivalent to HCIA-Data Center Facility and basic experience with data center infrastructure deployment. |
| Official Syllabus URL: | https://e.huawei.com/en/talent/#/cert/product-details?certifiedProductId=383 |
Huawei H12-425_V2.0-ENU Exam Syllabus Topics:
| Section | Objectives |
|---|---|
| Facility Deployment and Troubleshooting | - Deployment Practices
|
| Cooling Systems | - Cooling Technologies
|
| Huawei Data Center Infrastructure | - Data Center Fundamentals
|
| Power Supply and UPS Systems | - Power Distribution
|
| Modular Data Center Solutions | - FusionModule Series
|
| Monitoring and Management Systems | - Management Platforms
|
| Battery Systems | - Energy Storage Solutions
|
Huawei HCIP-Data Center Facility Deployment V2.0 Sample Questions:
Question 1
The form of humidifier adopted by the row-level chilled water intelligent temperature control product NetCol5000-C032H is (______). (Fill in the blank)
Question 2
UPS5000-series modular UPS product features are similar to which of the following product models?
A. APM
B. NXr
C. 80-NET
D. Hipulse-u
Question 3
In the UPS5000 configuration, different battery schemes can be obtained by adjusting the number of battery strings and the number of battery cells in a single group.
A. True
B. False
Question 4
When the NETCOL5000-A air conditioner is turned on for commissioning, the possible cause of the exhaust high pressure alarm, which is incorrect?
A. Too much cold dish charge
B. Outdoor fan speed pot bottom
C. The outdoor fan cannot be started
D. Too little cold dish charge
Question 5
Which of the following statements is true about UPS5000 power modules and bypass modules?
A. The power module capacity of both the UPS5000-S and UPS5000-E is 50 kVA. Therefore, the two types of UPS can be used together.
B. The UPSS000-E-200K and UPS5000-E-400K use the same power module and provide the same capacity of 50 kVA but have different numbers of power modules.
C. The power modules used in the UPSS000-S-1200K are the same as those used in the UPS5000-E-200K.
D. For UPSs of the same model but in different power segments, their bypass module capacity is the same.